Project stories
Short stories from completed rehabilitation and inspection projects: the problem, how it was solved and the result.
Rehabilitation
Renewing pipes without digging.

Rehabilitation · Drain-lines · Singapore
16 km of drain-lines, relined beneath busy housing estates
Trenchless renewal of 150 mm to 300 mm sanitary drain-lines, carried out while residents went about their day.
Read the story →
Rehabilitation · Trunk sewer · Singapore
10 km of trunk sewer, relined with the flow still running
Spiral-wound lining for sewers from 600 mm up to 2.2 m in diameter.
Read the story →
Rehabilitation · Seawater cooling · Singapore
DN1500 and DN1800 seawater cooling lines, relined with UV-cured GRP
Large-diameter cooling pipes renewed from the inside, worked from access pits.
Read the story →
Rehabilitation · Water treatment plant
Two weeks, one shutdown: relining pipework inside a working waterworks
More than 50 m of corroded DN450 and DN600 pipe renewed without stopping the plant.
Read the story →
Rehabilitation · Public park
Bringing a 135 m water main back to full bore, under a public park
Heavy corrosion cleared and the main relined from compact pits, with the park open throughout.
Read the story →
Rehabilitation · Housing estate
CIPP and spray lining, combined to renew a DN700 main beneath a housing estate
Bends, branches and diameter changes, under a courtyard, a car park and a supermarket loading bay.
Read the story →
Rehabilitation · Water main
One liner, four 45° bends
A custom-made liner followed a 55 m DN620 main through every change of direction.
Read the story →
Rehabilitation · Urban road
310 m of encrusted water main, renewed in two sections
Heavy scale removed and the geometry checked before CIPP and spray lining went in.
Read the story →
Rehabilitation · Secure estate
240 m relined in two weeks, next to a secure estate and a school
Security clearance, school hours and airfreighted materials, all within one short window.
Read the story →
Rehabilitation · Industrial plant
More than 3 km of fire-water mains, renewed inside a working plant
Pressure CIPP for DN100 to DN450 lines, with each work package designed on its own.
Read the story →Inspection
Seeing inside, without shutting down.

Inspection · City centre
800 m of live water main inspected in two days, with no shutdown
A tethered probe travelled with the flow, sending back live CCTV and leak data.
Read the story →
Inspection · Water main
A baseline survey of a large water main, while it stayed in service
130 m surveyed upstream from an air valve to a DN1800 butterfly valve.
Read the story →
Inspection · Transmission main · Middle East
1.8 km of DN400 transmission main inspected through a 130 mm opening
Visual inspection and acoustic leak detection, through existing DN150 air valves.
Read the story →
Inspection · Water supply · Thailand
Two pipelines, two materials, two days: 633 m inspected
DN300 PVC and DN1200 steel mains surveyed through DN150 valve access.
Read the story →Contact
Tell us about your pipeline.
Share the location, pipe size and material, length and the problem you are seeing. We will reply with next steps.
- Coimbatore office
- 12B, Door No. 1996/7A, MR Garden
Narayana Avenue, Krishna Colony
Coimbatore, Tamil Nadu 641015, India - Telephone
- +91 97510 53539

