Perma-Liner Industries India Pvt. Ltd.

Rehabilitation · Seawater cooling · Singapore

DN1500 and DN1800 seawater cooling lines, relined with UV-cured GRP

Large-diameter cooling pipes renewed from the inside, worked from access pits.

Lifting the liner, lowering it into the access pit, and preparing the liner end.
Lifting the liner, lowering it into the access pit, and preparing the liner end.
Pipe
DN1500 and DN1800
Service
Seawater cooling
Method
UV-cured GRP liner (Axion)
Shifts
Day and night

We recently completed the rehabilitation of seawater cooling lines at an industrial site in Singapore. The pipes are DN1500 and DN1800, and the work was done in two phases, on day and night shifts.

Each line was flushed, jetted and inspected by CCTV before lining. A glide foil went in first. The Axion UV-cured GRP liner was then strapped, lifted by crane and pulled in from the access pit. Packers and end caps were fitted, the liner was inflated against the host pipe, and a UV light train was run through it to cure it.

After cooling, the liner ends were cut and sealed, and any finishing patches were made inside the pipe. A post-lining CCTV survey was carried out on every section before handover.

Crane lift of the liner at first light, directed by the lifting supervisor.
Crane lift of the liner at first light, directed by the lifting supervisor.
Strapping the liner end before the lift.
Strapping the liner end before the lift.

Figures are taken from the project records. Client and site names are withheld.